Search results for "imaging [Stars]"

showing 10 items of 415 documents

Characterisation of indeterminate focal breast lesions on grey-scale ultrasound: role of ultrasound elastography.

2011

PURPOSE: This study was undertaken to evaluate the role of ultrasound (US) elastography in characterising focal breast lesions classified as indeterminate on B-mode US. MATERIALS AND METHODS: Eighty-four focal breast lesions, 64 benign and 20 malignant (mean diameter, 15.1 mm), detected but not characterised on B-mode US in 72 women, Breast Imaging Reporting and Data System (BI-RADS) US category 3 (n=56) or category 4 (n=28), were studied with US elastography and classified in consensus by two radiologists according to a five-point colour scale. Sensitivity, specificity and positive and negative predictive values (PPV and NPV) of US elastography compared with conventional US were calculated…

Adultmedicine.medical_specialtyBreast NeoplasmsGrey scaleSensitivity and SpecificityDiagnosis DifferentialElasticity Imaging TechniquesPredictive Value of TestsmedicineUltrasound elastographyHumansRadiology Nuclear Medicine and imagingProspective StudiesNeuroradiologyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryUltrasoundInterventional radiologyGeneral MedicineMiddle AgedElasticity Imaging TechniquesFemaleRadiologyElastographyUltrasonography MammaryBreast Ultrasound elastography Breast neoplasmsbusinessIndeterminateSettore MED/36 - Diagnostica Per Immagini E RadioterapiaAlgorithms
researchProduct

Endo-neuro-sonography: principles and 3-D technique

1997

To evaluate the usefulness of transendoscopic sonography we studied two new sono probes 6 F in diameter in 17 fresh specimens. We saw precise imaging of well-known anatomical structures and also gained an additional dimension in endoscopy, as the sono adds to the endo-view a transverse scan like a mini-CT at the tip of the probe. We also experienced the navigation characteristic of this imaging technique, both in real time and on line. Some 3-D reconstructions of the ventricular system were examined. The equipment has been used in clinical practice and must now be adapted for neurosurgery.

Adultmedicine.medical_specialtyNeuronavigationmedicine.diagnostic_testbusiness.industryAnatomical structuresBrainEndoscopic anatomyGeneral MedicineEchoencephalographyEndosonographySurgeryEndoscopyClinical PracticeChild PreschoolPediatrics Perinatology and Child HealthImage Processing Computer-AssistedHumansMedicineNeurology (clinical)Imaging techniqueTomography X-Ray ComputedbusinessBiomedical engineeringChild's Nervous System
researchProduct

Split-Window Coefficients for Land Surface Temperature Retrieval From Low-Resolution Thermal Infrared Sensors

2008

In this letter, we provide a complete set of split-window coefficients that can be used to retrieve land surface temperature (LST) from thermal infrared sensors onboard the most popular remote-sensing satellites: ERS-ATSR2, ENVISAT-AATSR, Terra/Aqua-MODIS, NOAA series-AVHRR, METOP-AVHRR3, GOES series-IMAGER, and MSG1/MSG2-SEVIRI. The coefficients have been obtained by minimization from an extensive simulated database constructed from MODTRAN radiative transfer code calculations, emissivity spectra extracted from spectral libraries, and spectral response functions of the thermal bands considered. This letter also analyzes the magnitude of the error on the LST retrieval and the contribution t…

Advanced very-high-resolution radiometerMODTRANLookup tableRadiative transferEmissivityAtmospheric correctionEnvironmental scienceScale (descriptive set theory)Moderate-resolution imaging spectroradiometerElectrical and Electronic EngineeringGeotechnical Engineering and Engineering GeologyRemote sensingIEEE Geoscience and Remote Sensing Letters
researchProduct

Cardiac Micro–Computed Tomography Imaging of the Aging Coronary Vasculature

2012

Background— Alterations at the level of the coronary circulation with aging may play an important role in the evolution of age-associated changes in left ventricular (LV) fibrosis and function. However these age-associated changes in the coronary vasculature remain poorly defined primarily due to the lack of high resolution imaging technologies. The current study was designed to utilize cardiac micro–computed tomography (micro-CT) technology as a novel imaging strategy, to define the 3-dimensional coronary circulation in the young and aged heart and its relationship to LV fibrosis and function. Methods and Results— Young (2 months old; n=10) and aged (20 months old; n=10) Fischer rats unde…

Agingmedicine.medical_specialtyX-ray microtomographyBlood PressureArticleVentricular Dysfunction LeftCoronary circulationImaging Three-DimensionalFibrosisCoronary CirculationInternal medicineLv dysfunctionAnimalsMedicineRadiology Nuclear Medicine and imagingbusiness.industryMicro computed tomographyCoronary vasculatureImaging studyX-Ray Microtomographymedicine.diseaseFibrosisSettore MED/11 - Malattie Dell'Apparato CardiovascolareRats Inbred F344Ratsmedicine.anatomical_structureBlood pressureEchocardiographyHigh resolution imaging techinques.Linear ModelsCardiologyCardiology and Cardiovascular MedicinebusinessCirculation: Cardiovascular Imaging
researchProduct

Caractérisation quantitative de la pulvérisation de pesticides par imagerie

2015

In recent years, advances in plant protection have contributed considerably to increasing crop yields in a sustainable way. Easy to apply and rather inexpensive, pesticides have proven to be very efficient. However, when pesticides are applied to crops some of the spray may not reach the target, but move outside the intended spray area. This can cause serious economic and environmental problems. Most of the pesticides are applied using agricultural sprayers. These sprayers use hydraulic nozzles which break the liquid into droplets with a wide range of droplet sizes and velocities and determine the spray pattern. Small droplets are prone to wind drift, while large droplets can runoff from th…

Agriculture and Food Sciencesspray angledroplet characterization[SDV]Life Sciences [q-bio]Générateur de gouttelettesBuses hydrauliquespiezoelectric droplet generator;high-speed imaging technique;image processing;spray angle;spray shape;droplet characterization;spray nozzlesImagerie rapideimage processingCaractérisation gouttelettepiezoelectric droplet generatorspray shapehigh-speed imaging techniquespray nozzlesAngle de pulvérisationtheseTraitment d’image[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing
researchProduct

Quantitative colorimetric analysis of some inorganic salts using digital photography

2011

An analytical imaging approach to the quantitation of dissolved chemical species absorbed in the visible spectral region is reported. The approach uses digital images of a series of standard solutions of the target substance and their processing with appropriate software to assign a numeric value to each standard in terms of color intensity. Such a value is directly proportional to the analyte concentration and allows the construction of a calibration graph. The results thus obtained are compared with those provided by the classical spectrophotometricmethod used to run calibration curves for colored substances. The chemical imaging technique is relative simple and affordable; in fact, it ca…

AnalyteINGENIERIA DE LA CONSTRUCCIONbusiness.product_categoryChemistrybusiness.industryCalibration curveBiochemistry (medical)Clinical BiochemistryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONAnalytical chemistryDigital photographyColorimetric-imaging analysisStandard solutionBiochemistryAnalytical ChemistryDigital imageVisible spectrophotometryElectrochemistryComputer visionArtificial intelligenceNumeric ValuebusinessColorimetric analysisSpectroscopyDigital camera
researchProduct

Plasmonic Nanosensor Array for Multiplexed DNA-based Pathogen Detection

2019

In this research we introduce a plasmonic nanoparticle based optical biosensor for monitoring of molecular binding events. The sensor utilizes spotted gold nanoparticle arrays as sensing platform. The nanoparticle spots are functionalized with capture DNA sequences complementary to the analyte (target) DNA. Upon incubation with the target sequence, it will bind on the respectively complementary functionalized particle spot. This binding changes the local refractive index, which is detected spectroscopically as the resulting changes of the localized surface plasmon resonance (LSPR) peak wavelength. In order to increase the signal, a small gold nanoparticle label is introduced. The binding ca…

AnalyteMaterials scienceta221Molecular bindingMetal NanoparticlesNanoparticleBioengineering02 engineering and technologybiosensorit01 natural sciencesSensor arrayLimit of DetectionNanosensorplasmonic arrayNanotechnologyLSPR sensingSurface plasmon resonanceDNA FungalInstrumentationPlasmonCandidaDNA detectionFluid Flow and Transfer ProcessesPlasmonic nanoparticlesBase Sequenceta114business.industryProcess Chemistry and Technology010401 analytical chemistryta1182Fourier-transform-imaging spectroscopynanobiotekniikkaDNASurface Plasmon Resonance021001 nanoscience & nanotechnologyplasmonic nanoparticles0104 chemical sciencesAspergillusOptoelectronicsnanohiukkasetGoldDNA Probes0210 nano-technologybusinessACS Sensors
researchProduct

RESIST-HCV Criteria to Monitor Progression of Low-Risk Esophageal Varices in Patients With Compensated Cirrhosis After HCV Eradication: The SIMPLE St…

2022

Noninvasive criteria to predict the progression of low-risk esophageal varices (EV) in patients with compensated hepatitis C virus (HCV) cirrhosis after sustained virological response (SVR) by direct-acting antivirals (DAAs) are lacking. Our aim was to assess the diagnostic performance of Rete Sicilia Selezione Terapia-HCV (RESIST-HCV) criteria for EV progression compared with elastography-based criteria (Baveno VI, Expanded Baveno VI, and Baveno VII-HCV criteria).All consecutive patients observed at 3 referral centers with compensated HCV cirrhosis with or without F1 EV who achieved sustained virological response by DAAs were classified at last esophagogastroduodenoscopy (EGDS) as RESIST-H…

Antiviral AgentMaleLiver CirrhosisHepatologyPlatelet CountLiver CirrhosiGastroenterologyHepacivirusHepatitis C ChronicEsophageal and Gastric VaricesAntiviral AgentsElasticity Imaging Techniques.Esophageal and Gastric VariceHumansElasticity Imaging TechniquesFemaleSerum AlbuminHumanAgedThe American journal of gastroenterology
researchProduct

Methods to Evaluate Lighting Quality in Educational Environments

2015

Abstract The current standard for lighting of indoor work places (EN 12464-1) essentially prescribes values of photometric quantities (illuminance, Unified Glare Index, etc.); therefore it does not allow a comprehensive analysis of the luminous environment. In Italy, educational buildings do not always comply with the standard requirements for lighting. Therefore an analysis of their current state is needed and this paper illustrates two methods, developed by the authors, to carry out this investigation: the former is based on the analysis of luminance maps obtained through the HDR imaging technique whereas the latter focuses on the evaluation of non-visual effects of light.

Architectural engineeringNon-visual responseComputer sciencemedia_common.quotation_subjecteducational environmentsLighting qualityGlare (vision)IlluminanceLuminancenon-visual responsesEnergy (all)Energy(all)Work (electrical)HDR imagingDaylightDaylightQuality (business)Imaging techniqueEducational environmentSmart lightingdaylight.Simulationmedia_commonEnergy Procedia
researchProduct

A Fast Imaging Technique Applied to 2D Electrical Resistivity Data

2014

A new technique is proposed to process 2D apparent resistivity datasets, in order to obtain a fast and contrasted resistivity image, useful for a rapid data check in field or as a starting model to constrain the inversion procedure. In the past some modifications to the back-projection algorithm, as well as the use of filtering techniques for the sensitivity matrix were proposed. An implementation of this technique is proposed here, considering a two-step approach. Initially a damped least squares solution is obtained after a full matrix inversion of the linearized geoelectrical problem. Furthermore, on the basis of the results, a subsequent filtering algorithm is applied to the Jacobian ma…

Article SubjectComputer sciencelcsh:QC801-809Apparent resistivityInversion (meteorology)Least squaresSynthetic datalcsh:Geophysics. Cosmic physicssymbols.namesakeGeophysicsElectrical resistivity and conductivityFull matrixSettore GEO/11 - Geofisica ApplicataJacobian matrix and determinantsymbolsImaging techniqueAlgorithmERT back-projection LSQR inversion resistivityWater Science and TechnologyInternational Journal of Geophysics
researchProduct